Industrial Protocols: Ethernet/IP

Able to communicate with any device that implements Ethernet/IP Explicit Messaging, these blocks are useful for connecting to automation equipment and controllers and other generic CIP devices.


Unpacking Binary Data From a Device

For every signal processed, both the EIPGetAttribute and EIPSetAttribute blocks will execute a single request to a target device, and emit a signal containing the results of that request. The path of CIP objects and the attributes available is defined by the target device manufacturer. In the case of getting an attribute, the outgoing signal will contain the configured host and object path, and most importantly a value attribute that contains some raw bytes like {"value": b"\xbf\x80\x00\x00"}. Generally the easiest way to deal with this binary data is to use an UnpackBytes block to build a real number. The method of interpretation for this data is provided by the device vendor, and a New Signal Attrbute configured following that method:

                      ...
                       |
                       |
                       V
+----------------------O--------------------+
| EIPGetAttribute                           |
|   Hostname: <host>                        |
|   Class ID: <id>                          |
|   Instance: <inst>                        |
|   Attribute: <attr>                       |
+----------------------O--------------------+
                       |
                       |
                       V
+----------------------O--------------------+
| UnpackBytes                               |
|   New Signal Attributes:                  |
|     New Attribute Key: {{ $host }}_temp_C |
|     Bytes To Unpack: {{ $value }}         |
|     Format: float                         |
|     Endian: big                           |
|   Exclude Existing Fields: True           |
+----------------------O--------------------+
                       |
                       |
                       V
            {"<host>_temp_C": -1.0}

If for example the device manual specifies that this is an IEEE 754 floating point number (big endian) the value ultimately decodes to -1.0. The precision of this float is inferred from the number of bytes to unpack and does not need to be configured. By selecting Exclude Existing Fields the final signal in this diagram contains only the unpacked vale in the new attribute(s) configured.

Setting an attribute is very similar, using PackBytes to store an integer or float into the specified number of bytes (therefore defining the range of integers, or precision of floats).

To interact with an Allen-Bradley CongtrolLogix or CompactLogix controller, see the ReadTag and WriteTag blocks specific for those devices.